Tips for Site engineers;

CLEAR COVER TO MAIN REINFORCEMENT:
Footings : 50 mm
Raft Foundation (Top) : 50 mm
Raft Foundation (Bottom) : 75 mm
Raft Foundation (Side) : 75 mm
Beam : 25 mm
Strap Beam : 50 mm
Column :40 mm
Slab : 15 mm
flat Slab : 20 mm
Staircase : 15 mm
Retaining Wall : 20 – 25 mm
Water Retaining Structures : 2 0- 30 mm
Maximum water absorption by bricks – 15%
Compressive strength of bricks – 3.5 N/mm2
Density Of Bricks- 1600-1920 Kg/m3
Minimum thickness of slab – 125 mm
Dimension tolerance for cubes – +2
Maximum free fall of concrete – 1.50 m
Lapping should not be used for the bars having larger dia than 36 mm.
Binding wire required for steel reinforcement – 8 kg per MT
3 samples should be taken for every 100 m2 in core cutting test.
Maximum chair spacing – 1 m.
Minimum dia should be used in dowels rod – 12 mm.
Hook for strriups (one side) – 9D
No. of strriups = (clear span/spanning) + 1
Length of main steel in cantilever anchorage – 69D.
Minimum no. of bars in square column – 4
Minimum no. of bars in circular column – 6
Minimum dia of main bars and distributors in the slab – 8 mm.
Maximum dia of main bars and distributors in the slab – 1/8 of slab thickness.
All reinforcement should be free from mill scales, loose rust, and coats of paints, oil or any other substances.